Syed Humayun Basha
开通时间:..
最后更新时间:..
点击次数:
发表刊物:Thin-Walled Structures, Elsevier
摘要:A new-type of fabricated coupled composite column (CCC) system composed of closely spaced double small-section concrete filled steel tubes (CFST) connected by steel connector beams using blind bolts was proposed. An experimental investigation and finite element analysis were carried out by testing CCC specimens and CFST column counterparts for various eccentricity ratios and connector beam configurations. The column limbs of the fabricated specimens performed well together combinedly and deformed as a whole without connection failure. The axial load-carrying capacity found to be decreased by 20% when the eccentricity ratio was increased from 0.2 to 0.4. Theoretical analysis was carried out to estimate the modified slenderness ratio required to calculate the capacity of the specimens. Effectiveness of various design standards to predict the capacity of CCC and traditional CFST built-up columns from past studies were also verified. Chinese design standard provided closest predictions to the test results, with the average ratio of the predicted strength to the experimental strength approximately equal to 0.868. The proposed coupled composite columns can be conveniently used in multi-storey assembled frame structures.
论文类型:期刊论文
学科门类:工学
一级学科:土木工程
文献类型:J
卷号:160
页面范围:107385
是否译文:否
发表时间:2020-12-22
收录刊物:SCI
DOI码:10.1016/j.tws.2020.107385
发布期刊链接:https://www.sciencedirect.com/science/article/pii/S0263823120312507